Example of Application Result


8,500kVA-600min-1 Vertical hydro generator coupled to 4 jet Pelton turbine

  Wet Wall by Conventional Seal --> Dried Wall by Brush Seal  
  Oil leakage through labyrinth seal occurred when turbine operated with 1 jet unbalanced radial thrust.
Pit wall was wet with leaked oil.
  Eight months after application of brush type seal, oil leakage is completely stopped.
Pit wall is dried without oil.
 


 