TOSHIBA Top Page

Power Systems Company
Toshiba Worldwide
Language selector Japanese
Products & Services
For Toshiba's generators
Life Estimation & Maintenance of Generator Stator Coil Insulation
Maintenance Seminar
For Non-Toshiba's generators
Generator Stator Coil Rewindings
  Newly Generator Insulation system
  Reasons for Stator Rewinding
Generator Replacement
Troubleshooting for Non-OEM Turbine Generators
Example
Up-rating
Efficiency Improvement
Easy Maintenance
High Operability
Site Search


Thermal Power
  Home > Thermal Power > Services & Maintenance > Generators & Electrical Systems >

Rehabilitation & Repairing

 

Reasons for Stator Rewinding


< Conventional Type Stator Winding >

In general, the dielectric strength level of generator stator winding insulation deteriorates to the safe operating level in around 30 years depending on operating conditions. When the generator reaches this level, some proper refurbishment works are necessary. There is no way to recover the performance of winding insulation perfectly without it's full renewal, So, stator rewinding is necessary for future safe operation, and is the best solution for the generator. Conventional Type Stator Winding


< Water- Cooled Stator Winding >

In the case of water-cooled stator winding, "Wet-heat Deterioration of Insulation" may happen.
It is caused by leakage of cooling water.
If wet-heat deterioration is caused on stator winding insulation, the dielectric strength level of insulation deteriorates remarkably.
In this case, some proper refurbishment works should be done to the generator as soon as possible.
So, stator rewinding is necessary for future safe operation, and is the best solution for the generator.
Water- Cooled Stator Winding
Capacitance measuring Robot

Generator Stator Coil Rewinding

 
To Top
  Site Map | Contact Us | Terms and Conditions | Privacy Policy Copyright (C)