Typical Repair for Steam Turbine


If some damage is observed on the major components of a steam turbine at periodic inspection etc., repair is necessary.
Typical damage and repairs are summarized as follows.

Typical Damage Repair (Reference)
Bowing of Turbine Rotor Balancing with Additional Weight (If Little Bowing)
Shaft-center Shifting by Re-Machining (If Much Bowing)
Erosion on Horizontal Surface of Casing Welding Repair
Machining the Horizontal Surface
Erosion on Nozzle Partition of Nozzle Box Welding Repair (If Little Erosion)
Replacement of Completed Nozzle Partition Portion (If Much Erosion)

Erosion/Corrosion on Nozzle Partition of Nozzle Diaphragm

Welding repair and Special Surface Coating
Damage of Bearing Replacement of White-metal on Bearing Surface (Except Pad Type and Liner Type Bearing)

 